Buckling Safety Factor
Compare applied compressive load with either a supplied critical load or the ideal Euler critical load.
Inputs
Formula
n = Pcr/P; Euler option: Pcr = π²EI/(KL)²
- n — ratio of critical to applied compressive load; not a certified design value
- n = Pcr/P = 20000/5000 = 4.
- Critical load is user supplied.
- This comparison is not a certified column design.