RL Time Constant & Transient
Calculate an ideal first-order RL step or current decay and plot current versus time. Switching transients, winding resistance beyond entered R and saturation are omitted.
Inputs
Formula
τ = L/R; step: i = (V/R)(1 − e^(−t/τ)); decay: i = I0e^(−t/τ)
- τ — L/R time constant
- i(t) — inductor current
- τ = L/R = 0.1/10 = 0.01 s
- i(t) = (V/R)(1 − e^(−t/τ)) = 0.6321205588285577 A
- Ideal first-order RL model assumptions.